Oops! It appears that you have disabled your Javascript. In order for you to see this page as it is meant to appear, we ask that you please re-enable your Javascript!

Rua General Jardim, 846 cj 41 Higienópolis, São Paulo - SP


  Telefone: +55 (11) 3231-4638   (11) 99863-5577

02. Use of extensible internal device in the femur of young dogs

L. T. Justolin1, S. C. Rahal2, P. P. R. Baptista3, E. S. Yoname4, M. J. Mamprim5, J. C. C. Balieiro6

1,2Departments of Veterinary Surgery and Anesthesiology, and 5Animal Reproduction and Radiology, School of Veterinary Medicine and Animal Science, São Paulo State University (UNESP), Botucatu Campus, São Paulo, Brazil 3,4Department of Orthopedics and Traumatology, Santa Casa Medical School, São Paulo, Brazil 6Department of Basic Sciences, School of Animal Science, Pirassununga Campus, São Paulo University (USP), São Paulo, Brazil

Keywords

treatment, dog, femur, plate

Summary

An extensible internal device (EID) was developed to preserve growth plate during the treatment of fracture complications or segmental bone loss from tumour resection in children. Since this type of extensible, transphyseal, internal fixation device has only been used in a few paediatric cases; the aim of this study was to evaluate an in vivo canine study, a surgical application of this device, and its interference with longitudinal growth of the non-fractured distal femur. Ten clinically healthy two- to three-month-old poodles weighing 1.5–2.3 kg were used. Following a medial approach to the right distal femur, one extremity of the EID, similar to a T-plate, was fixed in the femoral condyle with two cortical screws placed below the growth plate. The other extremity, consisting of an adaptable brim with two screw holes and a plate guide, was fixed in the third distal of the femoral diaphysis with two cortical screws. The EID was removed 180 days after application. All of the dogs demonstrated full weight-bearing after surgery. The values of thigh and stifle circumferences, and stifle joint motion range did not show any difference between operated and control hindlimbs. The plate slid in the device according to longitudinal bone growth, in all but one dog. In this dog, a 10.5% shortening of the femoral shaft was observed due to a lack of EID sliding. The other dogs had the same longitudinal lengths in both femurs. The EID permits longitudinal bone growth without blocking the distal femur growth plate if appropriately placed.

 

Leia mais:

Use of extensible internal device in the femur of young dogs.

 

_____________________________________________

            Autor : Prof. Dr. Pedro Péricles Ribeiro Baptista

                         Oncocirurgia Ortopédica do Instituto do Câncer Dr. Arnaldo Vieira de Carvalho                   

Consultório: Rua General Jardim, 846 –  41  –  CEP: 01223-010   Higienópolis   São Paulo – S.P.

                        Fone: +55 11 3231-4638   Cel: +55 11 99863-5577   Email: pedro@oncocirurgia.com

_______________________________________________

 

Deixe uma resposta

O seu endereço de e-mail não será publicado. Campos obrigatórios são marcados com *